VSI has taken into consideration that the standard concrete vault panel may not be applicable to all end users. Some architects, designers, and engineers have specific weight restrictions for the modular vault system intended for a project and require a vault panel that is lightweight, but continues to provide the same security as that of the concrete vault panel. Typically this is the case in metropolitan areas where the modular vault is being installed in a multi-story building or the use of an elevator is needed.

The Vision vault panels are constructed out of pressurized laminate and completely enclosed in corrosion resistant galvanized steel. As with the standard concrete vault panels, the panels are sized to meet specific job and design requirements at half of the weight. The reduction in weight provides less installation restrictions and are perfect when installing in areas where access is limited.

 

 

 

 

Specifications

 

Steel Plate

Steel plate is used to create a floor for five-sided panel vaults.

 

The materials are pre-cut and numbered for installation.

 

Steel plate does not carry a U.L. rating and could compromise the integrity of the vaults.

 

When pricing steel plate for a floor, please allow for panels to sit on the plate.

 

Support Beams

Access and installation restrictions normally limit the maximum length of panels to 13 feet, regardless of class. To accommodate these restrictions, the standard maximum length of panels is set at 13 feet and an I‐beam is required for spans exceeding 13 feet. Modular support walls support the I‐beam, and the panels are inserted into the beam channel and welded.

 

Please contact engineering if your needs require longer panels.

 

Support Columns

When a vault requires beams that exceed 24 feet, a support column is sometimes required. VSI recommends cambering of the beams.

 

No Column Support

This optional method allows for support beams to be of any length.

Overall ceiling height is the only restriction, as the size of the I-beam increases.

Verify with VSI engineering staff prior to quoting.

 

Column Wrap

Some installations require the vault to be located in an area where an existing building support column is located. It is possible to incorporate the existing column into the vault. However, to maintain security levels, it is recommended that these columns be encased using vault panels with the same rating as the walls.

An alternative is to wrap the column in steel plate welded together and to the vault ceiling and floor.

 

Steel plate does not carry a U.L. rating and could compromise the integrity of the vaults.

 

Installations Supply Package

This package includes three sizes of shims, appropriate anchors and caulking.

In the event VSI performs the installation, these items are included in the installation charge.

 

Vent Ports

All VSI vent ports have been tested by U.L. to meet the standards set under Standard for Safety U.L. 680.

U.L. inspects manufacturing facilities periodically to verify these standards are adhered to.

 

The vent ports are incorporated into a special panel to facilitate the Heating/Air Conditioning Contractor. Vent Ports can be sized for airflow from 4" x 16" to 4" x 36". This adjustability should result in cost savings through the reduction in the use of ductwork. Provision is made to allow for the attachment of HVAC vents without jeopardizing the vault security.

 

Angle Iron

Angle iron is required on all five-sided vaults. The angle is secured to the vault floor and the panels are secured to it.

Angle Iron may be eliminated if the contractor embeds steel in the slab to allow the panels to be anchored.

 

Conduit Access

Each vault is equipped with six conduit connections for the electrical and alarm contractor.

Additional conduit connections are available.

These are installed in accordance with U.L. specifications.

 

Sprinkler Access

When required by local code, sprinkler access may be provided.

 

In accordance with U.L. specifications, these are limited to 1 1/4" ID and 1 1/2" OD.